METL-SPAN TS PANEL
Allowable Span for Inward or Outward Load of 5 psf
Thickness
(in)
Design Criteria Allowable
Span
(ft)
Bending
Stress
Shear
Stress
Deflection
Limit
Fastener
Capacity

4 30.9 79.9 26.3 49.8 26.3
5 33.6 94.0 30.1 57.9 30.1
6 36.7 104.7 33.9 66.1 33.9
7&8 40.4 112.1 37.8 74.2 37.8
  • Based on TS panel with 26 ga. exterior & 26 ga. interior face (min Fy = 33 ksi) for single span condition.
  • Allowable span is the lowest value of panel bending strength, shear strength, deflection limit and connection strength.
  • The spans based on panel stress and deflection design criteria are derived from E-72 structural testing. The allowable loads are calculated with a factor of safety of 2.5 and 3.0 for bending and shear stresses, respectively, and deflection limitation of L/240.
  • The connection strengths are derived from E-72 structural testing.and the allowable loads are calculated with a factor of safety of 2.5.
  • Based on attachment with 14 ga. steel girt with fastener spacing 3"-18"-18"-3" across panel width.
  • The structural capacity of the girts are not considered and must be examined independently.

 

METL-SPAN TS PANEL
(26 ga. Exterior & 26 ga. Interior Faces)
SINGLE SPAN CONDITION
TS
Panel
Design
Criteria
Allowable Load (psf)
Panel Span (ft)
5 6 7 8 9 10 11 12 13 14 15 16
4"
Thick
Bending & Shear 79.9 66.6 57.1 49.9 44.4 39.9 36.3 33.1 28.2 24.3 21.2 18.6
Deflection (L/240) 106.2 84.3 68.4 56.4 47.0 39.6 33.6 28.7 24.7 21.3 18.5 16.2
Connection F1 49.8 41.5 35.5 31.1 27.6 24.9 22.6 20.7 19.1 17.8 16.6 15.6
5"
Thick
Bending & Shear 94.0 78.3 67.2 58.8 52.2 47.0 42.7 39.2 33.5 28.9 25.2 22.1
Deflection (L/240) 124.3 99.7 81.8 68.2 57.6 49.1 42.1 36.4 31.6 27.6 24.2 21.3
Connection F1 57.9 48.3 41.4 36.2 32.2 29.0 26.3 24.1 22.3 20.7 19.3 18.1
6"
Thick
Bending & Shear 104.7 87.3 74.8 65.4 58.2 52.4 47.6 43.6 39.8 34.3 29.9 26.3
Deflection (L/240) 136.1 110.1 91.3 77.0 65.7 56.6 49.1 42.9 37.7 33.3 29.5 26.2
Connection F1 66.1 55.1 47.2 41.3 36.7 33.0 30.0 27.5 25.4 23.6 22.0 20.7
7"&8"
Thick
Bending & Shear 112.1 93.4 80.1 70.1 62.3 56.1 51.0 46.7 43.1 40.0 36.3 31.9
Deflection (L/240) 141.4 115.3 96.5 82.1 70.8 61.6 54.1 47.8 42.4 37.8 33.9 30.4
Connection F1 74.2 61.9 53.0 46.4 41.2 37.1 33.7 30.9 28.6 26.5 24.7 23.2
  • Based on TS panel with 26 ga. exterior & 26 ga. interior face (min Fy = 33 ksi). The panel span is single span condition.
  • Allowable positive load is the lowest value of panel bending strength, shear strength & deflection limit.
  • Allowable suction load is the lowest value of panel bending strength, shear strength, deflection limit and connection strength for each fastener pattern.
  • The loads based on panel stress and deflection design criteria are derived from E-72 structural testing. The allowable loads are calculated with a factor of safety of 2.5 and 3.0 for bending and shear stresses, respectively, and deflection limitation of L/240.
  • The connection strengths are derived from E-72 structural testing.and the allowable loads are calculated with a factor of safety of 2.5.
  • Based on attachment with 14 ga. steel girt with fastener spacing 3"-18"-18"-3" across panel width
  • The structural capacity of the girts are not considered and must be examined independently.

METL-SPAN TS PANEL
(26 ga. Exterior & 26 ga. Interior Faces)
TWO OR MORE SPANS CONDITION

TS
Panel
Design
Criteria
Allowable Load (psf)
Panel Span (ft)
5 6 7 8 9 10 11 12 13 14 15 16
4"
Thick
Bending & Shear 72.5 59.5 50.3 43.6 38.5 34.4 31.1 28.3 26.0 24.0 22.3 20.8
Deflection (L/240) 108.4 87.3 72.3 61.0 52.3 45.3 39.7 34.8 30.6 27.1 24.1 21.5
Connection F1 48.5 40.4 34.2 29.6 26.1 23.4 21.1 19.2 17.6 16.3 15.1 14.1
Connection F2 55.6 46.2 39.1 33.9 29.9 26.7 24.2 22.0 20.2 18.6 17.3 16.1
5"
Thick
Bending & Shear 86.4 70.9 59.9 51.9 45.7 40.8 36.9 33.7 30.9 28.5 26.5 24.7
Deflection (L/240) 125.9 102.0 84.9 72.1 62.1 54.1 47.6 42.3 37.7 33.6 30.1 27.1
Connection F1 49.9 41.4 35.0 30.3 26.7 23.9 21.6 19.7 18.1 16.7 15.5 14.4
Connection F2 60.7 50.1 42.4 36.7 32.3 28.9 26.1 23.8 21.9 20.2 18.7 17.5
6"
Thick
Bending & Shear 97.6 80.0 67.6 58.5 51.5 45.9 41.5 37.8 34.7 32.1 29.9 27.8
Deflection (L/240) 137.1 111.7 93.5 79.7 69.0 60.5 53.5 47.7 42.8 38.7 35.0 31.7
Connection F1 51.3 42.5 36.0 31.1 27.4 24.4 22.1 20.1 18.5 17.1 15.9 14.8
Connection F2 65.7 54.2 45.8 39.6 34.9 31.1 28.1 25.6 23.6 21.8 20.2 18.9
7"&8"
Thick
Bending & Shear 105.9 87.0 73.5 63.6 55.9 49.9 45.0 41.0 37.6 34.7 32.3 30.2
Deflection (L/240) 142.0 116.3 97.8 83.8 73.0 64.3 57.1 51.2 46.2 41.9 38.2 35.0
Connection F1 52.7 43.7 37.0 32.0 28.1 25.1 22.6 20.6 18.9 17.5 16.2 15.2
Connection F2 70.7 58.5 49.5 42.8 37.6 33.5 30.3 27.6 25.3 23.4 21.7 20.3
  • Based on TS panel with 26 ga. exterior & 26 ga. interior face (min Fy = 33 ksi) for 2 or more spans condition.
  • Allowable positive load is the lowest value of panel bending strength, shear strength & deflection limit.
  • Allowable suction load is the lowest value of panel bending strength, shear strength, deflection limit and connection strength for each fastener pattern.
  • The loads based on panel stress and deflection design criteria are derived from E-72 structural testing. The allowable loads are calculated with a factor of safety of 2.5 and 3.0 for bending and shear stresses, respectively, and deflection limitation of L/240.
  • The connection strengths are derived from E-72 structural testing.and the allowable loads are calculated with a factor of safety of 2.5.
  • Fastener Spacing across panel width into 14 ga. Girts:
    Connection F1 (3 Fasteners): End Support (3"-18"-18"-3") & Intermediate (7"-14"-14"-7")
    Connection F2 (4 Fasteners): End Support (3"-12"-12"-12-3") & Intermediate (5.25"-10.5"-10.5"-10.5"-5.25")
  • The structural capacity of the girts are not considered and must be examined independently.