Tests & Certifications

Test/Approval Test Method Test Title Results
Fire US ASTM E84 Surface Burning Characteristics of Building Materials Flame Spread 0, Smoke Developed 0
ASTM E119
CAN/ULC S101
UL 263
Fire Tests of Building Construction Materials Intertek Listings:
-4″ panel: 1 hour vertical or horizontal wall
-6″ panel: 2 hours vertical or horizontal wall
-8″ panel: 3 hours vertical or horizontal wall
-6″ panel: 1 1/2 hour ceiling or floor
ASTM E119
CAN/ULC S101
UL 263
Fire Tests of Building Construction Materials UL Listings:
-4″ panel: 1 hour vertical or horizontal wall
-7″ panel: 2 hours vertical or horizontal wall
-8″ panel: 3 hours vertical or horizontal wall
FM 4880 Class 1 Fire Rating of Insulated Interior Wall and Ceiling Panels Product Approved.

Exterior wall requires FM 4881 approval

ASTM E136 Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750C Non-Combustible at 750°C or 1382°F
Fire Canada ASTM E 119
CAN/ULC S101
UL 263
Fire Tests of Building Construction and Materials Intertek Listings:
-4″ panel: 1 hour vertical or horizontal wall
-6″ panel: 2 hours vertical or horizontal wall
-8″ panel: 3 hours vertical or horizontal wall
-6″ panel: 1 1/2 hours ceiling or floor
ASTM E119
CAN/ULC S101
UL 263
Fire Tests of Building Construction Materials UL Listings:
-4″ panel: 1 hour vertical or horizontal wall
-7″ panel: 2 hours vertical or horizontal wall
-8″ panel: 3 hours vertical or horizontal wall
CAN/ULC S102 Surface Burning Characteristics of Building Materials and Assemblies Flame Spread 0, Smoke Developed 0
Structural ASTM E72 Strength Tests of Panels for Building Construction See Load Charts
Thermal Performance ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus K-Factor of 0.275 BTU.in/hr.ft2.°F at 75°F mean core
Air Infiltration ASTM E283 Rate of Air Leakage Through Curtain Walls Under Specified Pressure Differences 0.04 cfm/ft2 at 12 psf
Water Infiltration ASTM E331 Water Penetration of Exterior Walls by Uniform Static Air Pressure Differences No uncontrolled leakage when tested to a static pressure of 20 psf
Special Approvals State of Florida Product Approval for the State of Florida Product has State of Florida approval