Tests & Certifications

Test Approval Test Method Test Title Results
Fire US/CAN ASTM E84 Surface Burning Characteristics of Building
Materials
Flame Spread < 25
Smoke Developed < 450
NFPA 259 Test Method for Potential Heat of Building Materials Potential heat of foam plastic insulation contained in the assembly tested in accordance with NFPA 285
NFPA 285 Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies See BW Stretch NFPA 285 Spec Sheet for complying wall assemblies
CAN/ULC S101 Fire Endurance Tests of Building Construction and Materials Meets Acceptance Criteria per the National Building Code of Canada
CAN/ULC S102 Surface Burning Characteristics of Building Materials and Assemblies Meets Acceptance Criteria per the National Building Code of Canada
CAN/ULC S134 Fire Test of Exterior Wall Assemblies Meets Acceptance Criteria per the National Building Code of Canada. Testing performed on panel only.
Structural ASTM E72 Strength Tests of Panels for Building Construction See load span tables
Thermal Performance ASTM C518 Steady-State Thermal Transmission Properties by Means of the Heat-Flow Meter Apparatus K-Factor of 0.147 BTU/h·ft²·°F at 75°F mean core
ASTM C1363 Thermal Performance of Building Materials and Envelope Assemblies See Thermal Performance Guide
Air Infiltration ASTM E2357 Rate of Air Leakage Through Curtain Walls Under Specified Pressure Differences Meets Acceptance Criteria per the International
Energy Conservation Code and the National
Energy Code of Canada.Maximum Air Infiltration Rate of 0.004 cfm/sq. ft. at a static-air-pressure difference of 1.57 psf
Water Infiltration ASTM E331 Water Penetration of Exterior Walls by Uniform Static Air Pressure Differences No uncontrolled leakage when tested to a static pressure of 15 psf for 15 minutes

No uncontrolled leakage when tested at a differential pressure of 6.24 psf for 2 hours (per International Build Code – Chapter 14)